We are a leading Manufacturer of water leak detection panel with modbus rtu, sontay water leak detection system (for server room/data center), j3 technology digital water leak detector, digital water leak detection system, water leak detection panel and water leak detection system from Mumbai, India.
₹ 6000 / Piece Get Latest Price
| Usage/Application | Data Centre, Server Room, Battery Room |
| Model Name/Number | WLD4ZMB |
| Display Type | Digital |
| Color | White |
| Material | M.S.Sheet |
| Body Material | MS |
| Operating Voltage | 12V AC |
| Power Source | 110-24V AC,50/60HZ |
| Sensor Cable length | Multiple by 5Mtr |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
WLD4ZMB (our Panel has Open Protocol)
The WLD4ZMB range of products is designed to detect water leaks at localised points using the cable sensor. All these sensors are used with the WLD4ZMB
microcontroller based intelligent panel that are suitable for wall mounting inside AHUs, power distribution units or general areas where leak detection is required. They are fitted as standard with LCD indication for healthy, fault & the water leak status. The external sounder can be muted by simply pressing the mute button. Existing water leak detection systems available in the market, uses a 12V /24V DC supply for sensing leaks. When DC excitation is used in the sensing cables they form electrolysis during the presence of water and forms corrosion around the sensing cables. This reduces the sensitivity over a period of time to virtually zero. However WLDM200 module uses AC as a sensing voltage, it does not corrode or degrade due to the alternating nature of the current and hence maintains the sensitivity of the sensing cables throughout its life time
The WLD4ZMB panel 4 relay outputs can either be utilised to integrate with BMS to activate individual zone alarm. The WLD4ZMB panel has built in MODBUS RTU port equipped with RS485 and hence can be integrated to any BMS software seamlessly.
Features .
₹ 10500 / Piece Get Latest Price
| Usage/Application | Data Centre, Server Room, BMS Room |
| Model Name/Number | WD-AMX1, WD-AMX2 |
| Display Type | Digital |
| Brand | Sontay |
| Body Material | Polymer |
| Operating Voltage | 24V DC OR 240V AC |
| Packaging Type | Secure Packaging for safe delivery to site |
| Sensor Cable length | Approx. 5mtr |
Minimum order quantity: 1 Piece
Sontay Water Leak Detection Controller & Water Leak Sensing Cable
₹ 6000 / Piece Get Latest Price
| Color | Siemens Grey |
| Power/Voltage | 24 Volts |
| Current | 1 Amp (Max.) |
| Display Type | Digital |
| Measurement Range | 30 meter |
| Material | Mild Steel |
| Continuous Working Time | Continuous |
| Brand | J3 Technology |
| Country of Origin | Made in India |
| Packaging | Box |
Due to our enormous understanding and massive knowledge of this business, we are involved in offering J3 Technology Digital Water Leak Detector.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
Water Leak Alarm Indication:
₹ 5500 / Piece Get Latest Price
| Display Type | Analog |
| Model Name/Number | J3 Technology |
| Brand | J3 Technology |
| Material | Mild Steel |
| Working Temperature | -20 Degree C to 70 Degree C |
| Measuring Frequency | 50 Hz |
| Battery Type | 12 Volt 7 AH 2 nos |
| Is It Portable | Non Portable |
| Country of Origin | Made in India |
| Voltage | 230 V AC |
Minimum order quantity: 5 Piece
Liquid leakage detection in a server room or datacentre.
Due to our enormous understanding and massive knowledge of this business, we are involved in offering 2 Zone Water Leak Detection System.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
WATER LEAK ALARM INDICATION:
The water leak Detection Panel shall monitor the status of all Sensor Cable on the zone for water, and the status of internal connection and interfaces including charger and batteries.
SALIENT FEATURE:
Micro controller based compact modular designed
The module enables a water alarm panel to be controlled by a state of the micro controller.
With built in 16 character LCD display.
Hustle free instant installation.
Soft touch type control and test switch on fascia.
Auto re-store after alarm / fault.
Provision for attachment of public address system and Auto dialer facility (optional)
Match with interior design of premises.
Custom built configuration possible with potential free for integration with Building management systems.
System can be integrated with all standard industry products.
Provision for alarm and fault repeaters.
Zonal panel dry contacts.
₹ 5500 / Piece Get Latest Price
| Display Type | Digital |
| Usage/Application | Server Room, Data Center, BMS Room |
| Model Name/Number | J3/Saini, Star, Synopsys |
| Brand | J3 Technology |
| Packaging Type | Box |
| Phase | Single Phase |
| Country of Origin | Made in India |
| Material | MS |
| Model | J3-C-099 |
| Usage | Server Room, Data Center, BMS Room |
Minimum order quantity: 1 Piece
Due to our enormous understanding and massive knowledge of this business, we are involved in offering Water Leak Detection System.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
₹ 5500 / Piece Get Latest Price
| Material | Powder Coated pannel |
| Voltage | 18V-28V |
| Display Type | Digital |
| Brand | J3 Technology |
| Model Name/Number | J3-Saini-Z2 |
| Measurement Range | 50HZ |
| Packaging Type | Standard |
Minimum order quantity: 1 Piece
TECHNICAL SPECIFICATIONOF PANEL
Model : J3-Saini-Z2 , J3-Saini -Z4 & J3-Saini-Z8
Power : AC220V/50HZ+10% and 24 AC
Voltage scope : 18v-28V
Charging voltage :27.6V
Charging current : 1AMP(MAX.)
EOL resister :4k7
Materials : M.S. Sheet 16SWG
Color : Siemens Gray
Dimension : 355 x 285 x 110mm approx..(up to 4 zone)
Weight : 4 kg. Approx. without bat.
Battery : 2 x 12 v/7 Ah
SILENCE FEATURE:
1. Micro controller based compact modular designed
2. The module enables a water alarm panel to be controlled by a state of the micro controller.
3. With built in 1 -line and 16-character LCD display
4. Hustle free instant installation.
5. Soft touch type control key and test switch on fascia.
6. Provision for attachment of public address system and Auto dialer facility(optional)
7. Match with interior design of premises.
8. Custom built -in configuration possible for integration with Building management system.
9. System can be integrated with all standard industry products.
10. Provision for alarm and fault repeaters.
11. Zone wise zonal panel dry contacts (optional)
₹ 5500 / Piece Get Latest Price
| Display Type | Digital |
| Material | Ms |
| Brand | Pqwt |
| Packaging Type | Box |
| Shape | Square |
| Type Product | WLD System |
Liquid leakage detection in a server room or datacentre.
Due to our enormous understanding and massive knowledge of this business, we are involved in offering Water Leak Detection System.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
WATER LEAK ALARM INDICATION:
The water leak Detection Panel shall monitor the status of all Sensor Cable on the zone for water, and the status of internal connection and interfaces including charger and batteries.
SALIENT FEATURE:
Micro controller based compact modular designed
The module enables a water alarm panel to be controlled by a state of the micro controller.
With built in 16 character LCD display.
Hustle free instant installation.
Soft touch type control and test switch on fascia.
Auto re-store after alarm / fault.
Provision for attachment of public address system and Auto dialer facility (optional)
Match with interior design of premises.
Custom built configuration possible with potential free for integration with Building management systems.
System can be integrated with all standard industry products.
Provision for alarm and fault repeaters.
Zonal panel dry contacts.
₹ 10500 / Piece Get Latest Price
| Measurement Range | 200 meter |
| Usage/Application | server room |
| Display Type | Digital |
| Body Material | MS |
| Sensor Cable length | 200 mtr |
| Country of Origin | Made in India |
TECHNICAL SPECIFICATIONOF PANEL
Model : J3-Saini-Z2 , J3-Saini -Z4 & J3-Saini-Z8
Power : AC220V/50HZ+10% and 24 AC
Voltage scope : 18v-28V
Charging voltage :27.6V
Charging current : 1AMP(MAX.)
EOL resister :4k7
Materials : M.S. Sheet 16SWG
Color : Siemens Gray
Dimension : 355 x 285 x 110mm approx..(up to 4 zone)
Weight : 4 kg. Approx. without bat.
Battery : 2 x 12 v/7 Ah
SILENCE FEATURE:
1. Micro controller based compact modular designed
2. The module enables a water alarm panel to be controlled by a state of the micro controller.
3. With built in 1 -line and 16-character LCD display
4. Hustle free instant installation.
5. Soft touch type control key and test switch on fascia.
6. Provision for attachment of public address system and Auto dialer facility(optional)
7. Match with interior design of premises.
8. Custom built -in configuration possible for integration with Building management system.
9. System can be integrated with all standard industry products.
10. Provision for alarm and fault repeaters.
11. Zone wise zonal panel dry contacts (optional)
₹ 6000 / Piece Get Latest Price
| Frequency | 60 Hz |
| Voltage | 220 V |
| Phase | Single Phase |
| Display Type | Digital |
| Product Type | Water Leak Detection System Supplier |
| Wire | 100 Mtr |
Minimum order quantity: 66 Piece
Due to our enormous understanding and massive knowledge of this business, we are involved in offering J3 Technology Digital Water Leak Detector.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
Water Leak Alarm Indication:
₹ 13000 / Piece Get Latest Price
| Material | Mild Steel |
| Display Type | Digital |
| Brand | J3 Technology |
| Usage/Application | Server Room , Battery Room , UPS Rooms , AC Tray |
| Resolution | 1mV |
| Voltage | 220 V |
| Frequency | 50 - 60 Hz |
| Input impedance | 10M |
| Detection depth | 200m |
| Power Frequency | 80dB |
TECHNICAL SPECIFICATIONOF PANEL
Model : J3-Saini-Z2 , J3-Saini -Z4 & J3-Saini-Z8
Power : AC220V/50HZ+10% and 24 AC
Voltage scope : 18v-28V
Charging voltage :27.6V
Charging current : 1AMP(MAX.)
EOL resister :4k7
Materials : M.S. Sheet 16SWG
Color : Siemens Gray
Dimension : 355 x 285 x 110mm approx..(up to 4 zone)
Weight : 4 kg. Approx. without bat.
Battery : 2 x 12 v/7 Ah
SILENCE FEATURE:
1. Micro controller based compact modular designed
2. The module enables a water alarm panel to be controlled by a state of the micro controller.
3. With built in 1 -line and 16-character LCD display
4. Hustle free instant installation.
5. Soft touch type control key and test switch on fascia.
6. Provision for attachment of public address system and Auto dialer facility(optional)
7. Match with interior design of premises.
8. Custom built -in configuration possible for integration with Building management system.
9. System can be integrated with all standard industry products.
10. Provision for alarm and fault repeaters.
11. Zone wise zonal panel dry contacts (optional)
₹ 10500 / Piece Get Latest Price
| Frequency | 50 Hz |
| Voltage | 230 Volts |
| Phase | Single Phase |
| Display Type | Analog |
| Measurement Range | 25 meter |
| Brand | J3 Technology |
| Working Temperature | -20 Degree C to 60 Degree C |
| Country of Origin | Made in India |
| Voltage Output | 12 - 24 V |
| Charging Voltage | 27.6 V |
Due to our enormous understanding and massive knowledge of this business, we are involved in offering Water Leak Detection System.
Other Details:
J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.
Cabinet :
The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.
Circuit:
Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'
Functioning Descriptions:
The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.
The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.
Get Latest Price
| Usage/Application | Server Room,Ups Room,Data Center,Critical rooms |
| Model Name/Number | J3WLD AMX - 2 |
| Display Type | Analog |
Get Latest Price
| Material | Mild Still |
| Display Type | Digital |
| Brand | J3/Saini |
| Packaging Type | BOX |
| Model Name/Number | J3-Saini-Z2 |
| Power Supply | 230 V |
| Power Consumption | Electric |
| Country of Origin | Made in India |
₹ 9000 / Piece Get Latest Price
| Display Type | Digital |
TECHNICAL SPECIFICATIONOF PANEL
Model : J3-Saini-Z2 , J3-Saini -Z4 & J3-Saini-Z8
Power : AC220V/50HZ+10% and 24 AC
Voltage scope : 18v-28V
Charging voltage :27.6V
Charging current : 1AMP(MAX.)
EOL resister :4k7
Materials : M.S. Sheet 16SWG
Color : Siemens Gray
Dimension : 355 x 285 x 110mm approx..(up to 4 zone)
Weight : 4 kg. Approx. without bat.
Battery : 2 x 12 v/7 Ah
SILENCE FEATURE:
1. Micro controller based compact modular designed
2. The module enables a water alarm panel to be controlled by a state of the micro controller.
3. With built in 1 -line and 16-character LCD display
4. Hustle free instant installation.
5. Soft touch type control key and test switch on fascia.
6. Provision for attachment of public address system and Auto dialer facility(optional)
7. Match with interior design of premises.
8. Custom built -in configuration possible for integration with Building management system.
9. System can be integrated with all standard industry products.
10. Provision for alarm and fault repeaters.
11. Zone wise zonal panel dry contacts (optional)
Mrs.Simran (Marketing Manager)
J3 Technology
B-23, Narayan Plaza Co. OP Soc Ltd, Near Hdfc Bank, Chandivali, Kurla West, Mumbai
Mumbai - 400072, Maharashtra, India