Call 08047634744 79% Response Rate

our range

Power Control Panel

Pioneers in the industry, we offer water leak detection panel and water leak detection panel with modbus rtu from India.
  • Water Leak Detection Panel
  • Water Leak Detection Panel
  • Water Leak Detection Panel
  • Water Leak Detection Panel
  • Water Leak Detection Panel
  • Water Leak Detection Panel
  • Water Leak Detection Panel
Water Leak Detection Panel

Water Leak Detection Panel

Rs 5,500  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Display TypeDigital
Usage/ApplicationServer Room, Data Center, BMS Room
Model Name/NumberJ3/Saini, Star, Synopsys
BrandJ3 Technology
Packaging TypeBox
PhaseSingle Phase
Power SourceElectric
MaterialMS
Voltage230 V
UsageServer Room, Data Center, BMS Room
ModelJ3-C-099
Frequency50 Hz
Country of OriginMade in India

Due to our enormous understanding and massive knowledge of this business, we are involved in offering Water Leak Detection System.

Other Details:

J3 Technology make water leak detection panels are designed to the latest technology confirm to international standards ensuring top quality performance and Absolut reliability and easy installation. Designed to compel with is -2189 -1999 and ip 54.


Cabinet :

The control panel cabinet is fabricated from crca sheet of 16 swg and is properly pretreated before. painted with power coated p.o. red / siemens grey / textured white. the cabinet is dust proof.


Circuit:

Control circuit are fully solid state consist of glossy epoxy circuit board(1.6 mm thick) and treated with a protec- tive layer of special lacquer for protection against corrosion. all the card are moduler concept and plug in type for inter-changeable. one sets of common NO/ NC/ C contacts are available in alarm conditions as per requirement'


Functioning Descriptions:

The water Leak Detection Panel is the central processing unit of the system, providing the audible and visual information to the user, initiating automatic alarm response sequences and providing the means by which the user interacts with the system.

The Water Leak Detection Panel shall be able to be easily configured to meet the exact detection zone and cause/ effects output requirement of the building.Each zone card shall be capable of providing 300mA current and shall maintain a minimum of 24v on the zone up to the full extent of the battery standby period.

 



Additional Information:

  • Production Capacity: 50 Per day
  • Delivery Time: 3 to 4 Working Days

View Complete details

get quote request a call back
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
  • Water Leak Detection Panel with Modbus RTU
Water Leak Detection Panel with Modbus RTU

Water Leak Detection Panel with Modbus RTU

Rs 8,500  / SetGet Best Price

Minimum Order Quantity: 1 Set

Product Brochure

Usage/ApplicationData Centre, Server Room, Battery Room
Model Name/NumberWLD4ZMB
Display TypeDigital
MaterialM.S.Sheet
ColorWhite
BrandJ3/Saini
Body MaterialMS
Operating Voltage12V AC
Power Source110-24V AC,50/60HZ
Sensor Cable lengthMultiple by 5Mtr
Country of OriginMade in India
4 Zone Water Leak Detection Panel

WLD4ZMB

The WLD4ZMB range of products is designed to detect water leaks at localised points using the cable sensor. All these sensors are used with the WLD4ZMB
 microcontroller based intelligent panel that are suitable for wall mounting inside AHUs, power distribution units or general areas where leak detection is required. They are fitted as standard with LCD indication for healthy, fault & the water leak status. The external sounder can be muted by simply pressing the mute button. Existing water leak detection systems available in the market, uses a 12V /24V DC supply for sensing leaks. When DC excitation is used in the sensing cables they form electrolysis during the presence of water and forms corrosion around the sensing cables. This reduces the sensitivity over a period of time to virtually zero. However WLDM200 module uses AC as a sensing voltage, it does not corrode or degrade due to the alternating nature of the current and hence maintains the sensitivity of the sensing cables throughout its life time

The WLD4ZMB panel 4 relay outputs can either be utilised to integrate with BMS to activate individual zone alarm. The WLD4ZMB panel has built in MODBUS RTU port equipped with RS485 and hence can be integrated to any BMS software seamlessly.

Features .

  • Monitor up to 200 meters of Conductive Fluid sensing cable .
  • Micro Controller based innovative technology. Configure up to 4 Zones 
  • Trigger individual Relay Output for each zone and activates common fire & Hooter relay. 
  • Access the devices remotely via remote BMS via MODBUS protocol. Zone names can be configured 
  • Log an extensive variety of events and alarms. 

 



Additional Information:

  • Delivery Time: 2-3 Days

View Complete details

get quote request a call back